Brain injections require precision targeting. In a process wher minute damage can be fatal to your results, size matters. Get the industry’s smallest dispense volume and finest needle with Neuro syringe technology from Hamilton Company
Targeted sample deliveryThe Neuros accurately dispenses 50 nL to 100 μL of sample through a reinforced, ultrathin gauge needle protected by a custom-designed sleeve. The fine gauge needle creates a smaller injection site which minimizes tissue damage and injection variability. Neuros syringes feature a blunt point (point style 3) or beveled 12° point (point style 4) so sample is delivered directly to the site. These syringes are crafted to have very little to no dead volume which preserves the maximum amount of buffer and solution.
Flexible options for a variety of usesNeuros technology is offered on several models from the 700 Microliter, 1700 Gastight, and 7000 Modified Microliter series. Each syringe offers two needle sleeve options. The sleeve with a blind stop is perfect for cannulated applications and ensures precise administration with an adjustable penetration depth. The version without a blind stop works best with stereotaxic holders. Both types provide an adjustable needle exposure of 020 mm.
Also, Neuros syringes are compatible with most infusion pumps and stereotaxic holders, allowing for an easy integration into existing processes.
Product Close-Up
產(chǎn)品信息:
65457-01 | 0.5 µL, Neuros Model 7000.5 KH, point style 3, SYR |
![]() | |
65457-02 | 0.5 µL, Neuros Model 7000.5 KH, point style 4, SYR |
![]() | |
65458-01 | 1.0 µL, Neuros Model 7001 KH, point style 3, SYR |
![]() | |
65458-02 | 1.0 µL, Neuros Model 7001 KH, point style 4, SYR |
![]() | |
65460-05 | 10 µL, Neuros Model 1701 RN, point style 3, SYR |
![]() | |
65460-06 | 10 µL, Neuros Model 1701 RN, point style 4, SYR |
![]() | |
65460-20 | 100 µL, Neuros Model 1710 RN, point style 3, SYR |
![]() | |
65460-21 | 100 µL, Neuros Model 1710 RN, point style 4, SYR |
![]() | |
65459-01 | 2.0 µL, Neuros Model 7002 KH, point style 3, SYR |
![]() | |
65459-02 | 2.0 µL, Neuros Model 7002 KH, point style 4, SYR |
![]() | |
65460-10 | 25 µL, Neuros Model 1702 RN, point style 3, SYR |
![]() | |
65460-11 | 25 µL, Neuros Model 1702 RN, point style 4, SYR |
![]() | |
65460-02 | 5 µL, Neuros Model 75 RN, point style 3, SYR |
![]() | |
65460-03 | 5 µL, Neuros Model 75 RN, point style 4, SYR |
![]() | |
65460-15 | 50 µL, Neuros Model 1705 RN, point style 3, SYR |
![]() | |
65460-16 | 50 µL, Neuros Model 1705 RN, point style 4, SYR |
![]() | |
65460-01 | Neuros Adapter Kit for 100 µL RN SYR and smaller, point style 3 |
![]() | |
65460-04 | Neuros Adapter Kit for 100 µL RN SYR and smaller, point style 4 |
![]() | |
65461-01 | Neuros Replacement NDL, 33 gauge, Small Hub RN NDL, 3.03 in, point style 3, 6/PK |
![]() | |
65461-02 | Neuros Replacement NDL, 33 gauge, Small Hub RN NDL, 3.03 in, point style 4, 6/PK |
![]() | |
|